(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Switch Condition
|
Specified Condition
|
|
All terminals
|
LOCK
|
10 kΩ or higher
|
|
2 (ACC) - 4 (AM1)
|
ACC
|
Below 1 Ω
|
|
1 (IG1) - 4 (AM1)
|
ON
|
|
2 (ACC) - 4 (AM1)
|
|
5 (AM2) - 6 (IG2)
|
|
1 (IG1) - 4 (AM1)
|
START
|
|
3 (ST1) - 4 (AM1)
|
|
5 (AM2) - 6 (IG2)
|
|
5 (AM2) - 7 (ST2)
|
If the result is not as specified, replace the ignition or starter switch assembly.
|